Product Use and Scope
Ardex TPO Roofing Membrane are waterproofing
membranes for roofs constructed to drain water to
gutters and drain outlets
on buildings
o complying with the structural requirements of
the NZ Building Code, and
o in all wind zones up to and including extra high
for buildings designed to NZS3604:2011 or up
to 3.0 kPa ULS pressure differential for
buildings specifically designed
where the membrane is applied to a plywood or
suspended concrete substrate
Certificate Holder
Ardex New Zealand Limited
32 Lane Street
Woolston
Christchurch
Ph: 03 3736909
Website: http://www.ardex.co.nz/
CodeMark Certification
Body
AsureQuality, 11 Hull Road,
Mt Maunganui
New Zealand
Tel. 0508 00 11 22
www.asurequality.com
This is to Certify
Ardex TPO Roofing Membrane
Product Description
Ardex TPO Roofing Membrane is a single ply; adhesive fixed, polyester weft reinforced thermoplastic
polyolefin waterproofing sheet membrane.
Ancillary Components:
Ardex WPM 623 TPO Flashing Ardex TPO Inside/Outside Corners
Ardex TPO Universal and Large Pipe Flashing Ardex TPO QuickSeam Flashing
Ardex WPM 642 Water Based Bonding Adhesive Ardex WPM 651 TPO Cut Edge Sealant
Ardex WPM 657 TPO General Purpose Sealant Ardex WPM 659 TPO Pourable Sealant
Ardex All Purpose Fasteners Ardex HD Seam Plate
Ardex Pressure Seal
Complies with the Building Code of New Zealand:
If installed and maintained in accordance with the conditions of this certificate, the Ardex TPO Roofing Membrane will
comply with;
B2 Durability - B2.3.1 (b)
E2 External Moisture - E2.3.2
F2 Hazardous Building Materials - F2.3.1
If installed and maintained in accordance with the conditions of this certificate, the Ardex TPO Roofing Membrane will
contribute to compliance with;
E2 External Moisture - E2.3.1
Subject to the following conditions and limitations:
Conditions
1. Ardex TPO Roofing Membrane must be designed and installed in accordance with the Ardex Waterproofing Systems Manual (March2013)
2. Ardex TPO Roofing membrane must be installed by Ardex New Zealand Limited approved applicators
3. The substrate structure must be designed to comply with E2.3.1 i.e. designed to shed precipitated moisture. The following details contribute to
those requirements without specific design:
a. the roof is constructed to a fall no less than 2 degrees (1:30), and
b. has no integral roof gardens
4. Allowance for deflection and settlement of the substrate must be made in the design to ensure falls are maintained and no ponding of water can
occur.
5. Ardex New Zealand Ltd will notify AsureQuality Ltd in accordance with Regulation 15 of the Building (Product Certification) Regulations 2008
Limitations
1. The design and construction of the substrate and movement and control joints is specific to each building and is outside the scope of this
certificate
2. The weather tightness design of all junctions on specifically designed buildings is outside the scope of this certificate.
Date of Issue
19
th
May 2016